From 0f859c77cddf4539ef4050e0997a425da77ab675 Mon Sep 17 00:00:00 2001 From: Ole Odendahl Date: Sun, 18 Dec 2022 17:27:43 +0100 Subject: [PATCH] Slightly improved power cluster with more values. --- code/nrf-connect/samples/zigbee/src/main.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/code/nrf-connect/samples/zigbee/src/main.c b/code/nrf-connect/samples/zigbee/src/main.c index a76b541..522acce 100644 --- a/code/nrf-connect/samples/zigbee/src/main.c +++ b/code/nrf-connect/samples/zigbee/src/main.c @@ -82,8 +82,8 @@ ZB_ZCL_DECLARE_REL_HUMIDITY_MEASUREMENT_ATTRIB_LIST( ZB_ZCL_DECLARE_POWER_CONFIG_BATTERY_ATTRIB_LIST_EXT( batt_attr_list, &dev_ctx.batt_attrs.voltage, - /*battery_size=*/NULL, - /*battery_quantity=*/NULL, + /*battery_size=*/ZB_ZCL_POWER_CONFIG_BATTERY_SIZE_OTHER, + /*battery_quantity=*/1, /*battery_rated_voltage=*/NULL, /*battery_alarm_mask=*/NULL, /*battery_voltage_min_threshold=*/NULL, @@ -163,7 +163,7 @@ void update_sensors_cb(zb_uint8_t arg) { return; } - // Battery voltlage in units of 100 mV. + // Battery voltage in units of 100 mV. uint8_t batt_voltage = sensors.batt.adc_read.millivolts / 100; prst_zb_set_attr_value(ZB_ZCL_CLUSTER_ID_POWER_CONFIG, ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_VOLTAGE_ID,