Custom Soil Moisture cluster works! :)
This commits adds a Soil Moisture cluster according to the one that exists in https://github.com/Koenkk/zigbee-herdsman/blob/master/src/zcl/definition/cluster.ts#L2570. The cluster Id is 1032 (I didn't find it in the official specs).
This commit is contained in:
parent
15b1d9d2a8
commit
f7373cc6da
4 changed files with 151 additions and 239 deletions
34
code/nrf-connect/samples/zigbee/src/attrs.h
Normal file
34
code/nrf-connect/samples/zigbee/src/attrs.h
Normal file
|
|
@ -0,0 +1,34 @@
|
|||
#ifndef _PRST_ZB_ATTRS_H_
|
||||
#define _PRST_ZB_ATTRS_H_
|
||||
|
||||
#include <zboss_api.h>
|
||||
|
||||
// Relative humimdity cluster - section 4.7.2.2.1.
|
||||
typedef struct {
|
||||
// 100x relative humidity (mandatory).
|
||||
zb_uint16_t rel_humidity;
|
||||
// 0x0000 – 0x270f (mandatory).
|
||||
zb_uint16_t min_val;
|
||||
// 0x0001 – 0x2710 (mandatory).
|
||||
zb_uint16_t max_val;
|
||||
} prst_rel_humidity_attrs_t;
|
||||
|
||||
// Power configuration cluster - section 3.3.2.2.3
|
||||
typedef struct {
|
||||
// Units of 100 mV. 0x00 - 0xff (optional, not reportable :()).
|
||||
zb_uint8_t voltage;
|
||||
// Units of 0.5%. 0x00 (0%) - 0xc8 (100%) (optional, reportable).
|
||||
zb_uint8_t percentage;
|
||||
// zb_uint8_t quantity;
|
||||
// zb_uint8_t size;
|
||||
// zb_uint8_t rated_voltage;
|
||||
// zb_uint8_t voltage_min_thres;
|
||||
// zb_uint8_t percentage_min_thres;
|
||||
} prst_batt_attrs_t;
|
||||
|
||||
// Soil moisture cluster.
|
||||
typedef struct {
|
||||
zb_uint16_t percentage;
|
||||
} prst_soil_moisture_attrs_t;
|
||||
|
||||
#endif // _PRST_ZB_ATTRS_H_
|
||||
|
|
@ -21,39 +21,18 @@
|
|||
#include <zigbee/zigbee_app_utils.h>
|
||||
#include <zigbee/zigbee_error_handler.h>
|
||||
|
||||
#include "attrs.h"
|
||||
#include "prst_zb_soil_moisture_defs.h"
|
||||
#include "zb_range_extender.h"
|
||||
|
||||
/* Device endpoint, used to receive ZCL commands. */
|
||||
#define APP_TEMPLATE_ENDPOINT 10
|
||||
|
||||
/* Type of power sources available for the device.
|
||||
* For possible values see section 3.2.2.2.8 of ZCL specification.
|
||||
*/
|
||||
// #define TEMPLATE_INIT_BASIC_POWER_SOURCE ZB_ZCL_BASIC_POWER_SOURCE_DC_SOURCE
|
||||
#define TEMPLATE_INIT_BASIC_POWER_SOURCE ZB_ZCL_BASIC_POWER_SOURCE_BATTERY
|
||||
|
||||
/* LED indicating that device successfully joined Zigbee network. */
|
||||
// #define ZIGBEE_NETWORK_STATE_LED DK_LED3
|
||||
|
||||
/* LED used for device identification. */
|
||||
// #define IDENTIFY_LED DK_LED4
|
||||
|
||||
/* Button used to enter the Identify mode. */
|
||||
#define PRST_ZIGBEE_ENDPOINT 10
|
||||
#define IDENTIFY_MODE_BUTTON DK_BTN4_MSK
|
||||
|
||||
/* Button to start Factory Reset */
|
||||
#define FACTORY_RESET_BUTTON IDENTIFY_MODE_BUTTON
|
||||
|
||||
#define PRST_BASIC_MANUF_NAME "b-parasite"
|
||||
|
||||
#define PRST_BASIC_MODEL_ID "b-parasite"
|
||||
|
||||
LOG_MODULE_REGISTER(app, LOG_LEVEL_INF);
|
||||
|
||||
/* Main application customizable context.
|
||||
* Stores all settings and static values.
|
||||
*/
|
||||
|
||||
struct zb_device_ctx {
|
||||
zb_zcl_basic_attrs_ext_t basic_attr;
|
||||
zb_zcl_identify_attrs_t identify_attr;
|
||||
|
|
@ -62,9 +41,9 @@ struct zb_device_ctx {
|
|||
prst_rel_humidity_attrs_t rel_humidity_attrs;
|
||||
// In units of 100 mV.
|
||||
prst_batt_attrs_t batt_attrs;
|
||||
prst_soil_moisture_attrs_t soil_moisture_attrs;
|
||||
};
|
||||
|
||||
/* Zigbee device application context storage. */
|
||||
static struct zb_device_ctx dev_ctx;
|
||||
|
||||
ZB_ZCL_DECLARE_IDENTIFY_ATTRIB_LIST(
|
||||
|
|
@ -97,58 +76,67 @@ ZB_ZCL_DECLARE_REL_HUMIDITY_MEASUREMENT_ATTRIB_LIST(
|
|||
&dev_ctx.rel_humidity_attrs.min_val,
|
||||
&dev_ctx.rel_humidity_attrs.max_val);
|
||||
|
||||
// ZB_ZCL_DECLARE_POWER_CONFIG_ATTRIB_LIST(
|
||||
// batt_attr_list,
|
||||
// &dev_ctx.batt_voltage,
|
||||
// NULL,
|
||||
// NULL,
|
||||
// NULL,
|
||||
// NULL,
|
||||
// NULL);
|
||||
|
||||
// https://devzone.nordicsemi.com/f/nordic-q-a/85315/zboss-declare-power-config-attribute-list-for-battery-bat_num
|
||||
#define bat_num
|
||||
ZB_ZCL_DECLARE_POWER_CONFIG_BATTERY_ATTRIB_LIST_EXT(
|
||||
batt_attr_list,
|
||||
&dev_ctx.batt_attrs.voltage,
|
||||
/*battery_size=*/NULL,
|
||||
/*battery_quantity=*/&dev_ctx.batt_attrs.quantity,
|
||||
/*battery_rated_voltage=*/&dev_ctx.batt_attrs.size,
|
||||
/*battery_quantity=*/NULL,
|
||||
/*battery_rated_voltage=*/NULL,
|
||||
/*battery_alarm_mask=*/NULL,
|
||||
/*battery_voltage_min_threshold=*/&dev_ctx.batt_attrs.voltage_min_thres,
|
||||
/*battery_voltage_min_threshold=*/NULL,
|
||||
/*battery_percentage_remaining=*/&dev_ctx.batt_attrs.percentage,
|
||||
/*battery_voltage_threshold1=*/NULL,
|
||||
/*battery_voltage_threshold2=*/NULL,
|
||||
/*battery_voltage_threshold3=*/NULL,
|
||||
/*battery_percentage_min_threshold=*/&dev_ctx.batt_attrs.percentage_min_thres,
|
||||
/*battery_percentage_min_threshold=*/NULL,
|
||||
/*battery_percentage_threshold1=*/NULL,
|
||||
/*battery_percentage_threshold2=*/NULL,
|
||||
/*battery_percentage_threshold3=*/NULL,
|
||||
/*battery_alarm_state=*/NULL);
|
||||
|
||||
PRST_ZB_ZCL_DECLARE_SOIL_MOISTURE_ATTRIB_LIST(
|
||||
soil_moisture_attr_list,
|
||||
&dev_ctx.soil_moisture_attrs.percentage);
|
||||
|
||||
// ZB_ZCL_DECLARE_TEMP_MEASUREMENT_ATTRIB_LIST2(
|
||||
// soil_moisture_attr_list2,
|
||||
// &dev_ctx.soil_moisture_attrs.percentage);
|
||||
|
||||
void prst_zcl_soil_moisture_init_server(void) {
|
||||
zb_zcl_add_cluster_handlers(PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE,
|
||||
/*cluster_check_value=*/NULL,
|
||||
/*cluster_write_attr_hook=*/NULL,
|
||||
/*cluster_handler=*/NULL);
|
||||
}
|
||||
|
||||
void prst_zcl_soil_moisture_init_client(void) {
|
||||
// Nothing.
|
||||
}
|
||||
|
||||
ZB_DECLARE_RANGE_EXTENDER_CLUSTER_LIST(
|
||||
app_template_clusters,
|
||||
basic_attr_list,
|
||||
identify_attr_list,
|
||||
temp_measurement_attr_list,
|
||||
rel_humi_attr_list,
|
||||
basic_attr_list);
|
||||
basic_attr_list,
|
||||
soil_moisture_attr_list);
|
||||
|
||||
ZB_DECLARE_RANGE_EXTENDER_EP(
|
||||
app_template_ep,
|
||||
APP_TEMPLATE_ENDPOINT,
|
||||
PRST_ZIGBEE_ENDPOINT,
|
||||
app_template_clusters);
|
||||
|
||||
ZBOSS_DECLARE_DEVICE_CTX_1_EP(
|
||||
app_template_ctx,
|
||||
app_template_ep);
|
||||
|
||||
/**@brief Function for initializing all clusters attributes. */
|
||||
static void app_clusters_attr_init(void) {
|
||||
/* Basic cluster attributes data */
|
||||
dev_ctx.basic_attr.zcl_version = ZB_ZCL_VERSION;
|
||||
dev_ctx.basic_attr.power_source = TEMPLATE_INIT_BASIC_POWER_SOURCE;
|
||||
// dev_ctx.basic_attr.mf_name
|
||||
dev_ctx.basic_attr.power_source = ZB_ZCL_BASIC_POWER_SOURCE_BATTERY;
|
||||
ZB_ZCL_SET_STRING_VAL(
|
||||
dev_ctx.basic_attr.mf_name,
|
||||
PRST_BASIC_MANUF_NAME,
|
||||
|
|
@ -159,81 +147,34 @@ static void app_clusters_attr_init(void) {
|
|||
PRST_BASIC_MODEL_ID,
|
||||
ZB_ZCL_STRING_CONST_SIZE(PRST_BASIC_MODEL_ID));
|
||||
|
||||
static zb_int16_t temperature_value = 27;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_TEMP_MEASUREMENT,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_TEMP_MEASUREMENT_VALUE_ID,
|
||||
(zb_uint8_t*)&temperature_value, ZB_FALSE);
|
||||
|
||||
static zb_int16_t rel_humidity = 3 * (UINT16_MAX / 4);
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_REL_HUMIDITY_MEASUREMENT,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_REL_HUMIDITY_MEASUREMENT_VALUE_ID,
|
||||
(zb_uint8_t*)&rel_humidity, ZB_FALSE);
|
||||
|
||||
static zb_uint8_t batt_voltage = 33;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_VOLTAGE_ID,
|
||||
(zb_uint8_t*)&batt_voltage, ZB_FALSE);
|
||||
|
||||
static zb_uint8_t batt_percentage = 33;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_PERCENTAGE_REMAINING_ID,
|
||||
(zb_uint8_t*)&batt_percentage, ZB_FALSE);
|
||||
|
||||
static zb_uint8_t batt_quantity = 31;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_QUANTITY_ID,
|
||||
(zb_uint8_t*)&batt_quantity, ZB_FALSE);
|
||||
|
||||
/* Identify cluster attributes data. */
|
||||
dev_ctx.identify_attr.identify_time =
|
||||
ZB_ZCL_IDENTIFY_IDENTIFY_TIME_DEFAULT_VALUE;
|
||||
}
|
||||
|
||||
/**@brief Function to toggle the identify LED
|
||||
*
|
||||
* @param bufid Unused parameter, required by ZBOSS scheduler API.
|
||||
*/
|
||||
static void toggle_identify_led(zb_bufid_t bufid) {
|
||||
static int blink_status;
|
||||
|
||||
// dk_set_led(IDENTIFY_LED, (++blink_status) % 2);
|
||||
ZB_SCHEDULE_APP_ALARM(toggle_identify_led, bufid, ZB_MILLISECONDS_TO_BEACON_INTERVAL(100));
|
||||
}
|
||||
|
||||
/**@brief Function to handle identify notification events on the first endpoint.
|
||||
*
|
||||
* @param bufid Unused parameter, required by ZBOSS scheduler API.
|
||||
*/
|
||||
static void identify_cb(zb_bufid_t bufid) {
|
||||
zb_ret_t zb_err_code;
|
||||
|
||||
if (bufid) {
|
||||
/* Schedule a self-scheduling function that will toggle the LED */
|
||||
ZB_SCHEDULE_APP_CALLBACK(toggle_identify_led, bufid);
|
||||
} else {
|
||||
/* Cancel the toggling function alarm and turn off LED */
|
||||
zb_err_code = ZB_SCHEDULE_APP_ALARM_CANCEL(toggle_identify_led, ZB_ALARM_ANY_PARAM);
|
||||
ZVUNUSED(zb_err_code);
|
||||
|
||||
// dk_set_led(IDENTIFY_LED, 0);
|
||||
}
|
||||
}
|
||||
|
||||
/**@brief Starts identifying the device.
|
||||
*
|
||||
* @param bufid Unused parameter, required by ZBOSS scheduler API.
|
||||
*/
|
||||
static void start_identifying(zb_bufid_t bufid) {
|
||||
ZVUNUSED(bufid);
|
||||
|
||||
if (ZB_JOINED()) {
|
||||
/* Check if endpoint is in identifying mode,
|
||||
* if not put desired endpoint in identifying mode.
|
||||
*/
|
||||
if (dev_ctx.identify_attr.identify_time ==
|
||||
ZB_ZCL_IDENTIFY_IDENTIFY_TIME_DEFAULT_VALUE) {
|
||||
zb_ret_t zb_err_code = zb_bdb_finding_binding_target(
|
||||
APP_TEMPLATE_ENDPOINT);
|
||||
PRST_ZIGBEE_ENDPOINT);
|
||||
|
||||
if (zb_err_code == RET_OK) {
|
||||
LOG_INF("Enter identify mode");
|
||||
|
|
@ -251,25 +192,13 @@ static void start_identifying(zb_bufid_t bufid) {
|
|||
}
|
||||
}
|
||||
|
||||
/**@brief Callback for button events.
|
||||
*
|
||||
* @param[in] button_state Bitmask containing buttons state.
|
||||
* @param[in] has_changed Bitmask containing buttons
|
||||
* that have changed their state.
|
||||
*/
|
||||
static void button_changed(uint32_t button_state, uint32_t has_changed) {
|
||||
if (IDENTIFY_MODE_BUTTON & has_changed) {
|
||||
if (IDENTIFY_MODE_BUTTON & button_state) {
|
||||
/* Button changed its state to pressed */
|
||||
} else {
|
||||
/* Button changed its state to released */
|
||||
if (was_factory_reset_done()) {
|
||||
/* The long press was for Factory Reset */
|
||||
LOG_DBG("After Factory Reset - ignore button release");
|
||||
} else {
|
||||
/* Button released before Factory Reset */
|
||||
|
||||
/* Start identification mode */
|
||||
ZB_SCHEDULE_APP_CALLBACK(start_identifying, 0);
|
||||
}
|
||||
}
|
||||
|
|
@ -278,92 +207,61 @@ static void button_changed(uint32_t button_state, uint32_t has_changed) {
|
|||
check_factory_reset_button(button_state, has_changed);
|
||||
}
|
||||
|
||||
/**@brief Function for initializing LEDs and Buttons. */
|
||||
static void configure_gpio(void) {
|
||||
int err;
|
||||
|
||||
err = dk_buttons_init(button_changed);
|
||||
if (err) {
|
||||
LOG_ERR("Cannot init buttons (err: %d)", err);
|
||||
}
|
||||
|
||||
// err = dk_leds_init();
|
||||
// if (err) {
|
||||
// LOG_ERR("Cannot init LEDs (err: %d)", err);
|
||||
// }
|
||||
}
|
||||
|
||||
/**@brief Zigbee stack event handler.
|
||||
*
|
||||
* @param[in] bufid Reference to the Zigbee stack buffer
|
||||
* used to pass signal.
|
||||
*/
|
||||
void zboss_signal_handler(zb_bufid_t bufid) {
|
||||
/* Update network status LED. */
|
||||
// zigbee_led_status_update(bufid, ZIGBEE_NETWORK_STATE_LED);
|
||||
|
||||
/* No application-specific behavior is required.
|
||||
* Call default signal handler.
|
||||
*/
|
||||
ZB_ERROR_CHECK(zigbee_default_signal_handler(bufid));
|
||||
|
||||
/* All callbacks should either reuse or free passed buffers.
|
||||
* If bufid == 0, the buffer is invalid (not passed).
|
||||
*/
|
||||
if (bufid) {
|
||||
zb_buf_free(bufid);
|
||||
}
|
||||
}
|
||||
|
||||
void update_sensors_cb(zb_uint8_t arg) {
|
||||
LOG_INF("Updating sensors");
|
||||
|
||||
static zb_uint8_t batt = 10;
|
||||
batt += 1;
|
||||
|
||||
LOG_INF("Updating sensonrs");
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
zb_zcl_set_attr_val(PRST_ZIGBEE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_VOLTAGE_ID,
|
||||
(zb_uint8_t*)&batt, ZB_FALSE);
|
||||
|
||||
static zb_uint8_t batt_percentage = 10;
|
||||
batt_percentage += 1;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
zb_zcl_set_attr_val(PRST_ZIGBEE_ENDPOINT, ZB_ZCL_CLUSTER_ID_POWER_CONFIG,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_PERCENTAGE_REMAINING_ID,
|
||||
(zb_uint8_t*)&batt_percentage, ZB_FALSE);
|
||||
|
||||
static zb_int16_t temperature_value = 27;
|
||||
temperature_value += 1;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_TEMP_MEASUREMENT,
|
||||
zb_zcl_set_attr_val(PRST_ZIGBEE_ENDPOINT, ZB_ZCL_CLUSTER_ID_TEMP_MEASUREMENT,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_TEMP_MEASUREMENT_VALUE_ID,
|
||||
(zb_uint8_t*)&temperature_value, ZB_FALSE);
|
||||
|
||||
static zb_int16_t rel_humi = 12;
|
||||
rel_humi += 1;
|
||||
zb_zcl_set_attr_val(APP_TEMPLATE_ENDPOINT, ZB_ZCL_CLUSTER_ID_REL_HUMIDITY_MEASUREMENT,
|
||||
zb_zcl_set_attr_val(PRST_ZIGBEE_ENDPOINT, ZB_ZCL_CLUSTER_ID_REL_HUMIDITY_MEASUREMENT,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, ZB_ZCL_ATTR_REL_HUMIDITY_MEASUREMENT_VALUE_ID,
|
||||
(zb_uint8_t*)&rel_humi, ZB_FALSE);
|
||||
|
||||
static zb_int16_t soil_moisture = 69;
|
||||
soil_moisture += 1;
|
||||
zb_zcl_set_attr_val(PRST_ZIGBEE_ENDPOINT, PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID,
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_VALUE_ID,
|
||||
(zb_uint8_t*)&soil_moisture, ZB_FALSE);
|
||||
|
||||
ZB_SCHEDULE_APP_ALARM(update_sensors_cb, NULL, ZB_TIME_ONE_SECOND * 1);
|
||||
}
|
||||
|
||||
void main(void) {
|
||||
LOG_INF("Starting Zigbee application template example");
|
||||
|
||||
/* Initialize */
|
||||
configure_gpio();
|
||||
register_factory_reset_button(FACTORY_RESET_BUTTON);
|
||||
|
||||
/* Register device context (endpoints). */
|
||||
ZB_AF_REGISTER_DEVICE_CTX(&app_template_ctx);
|
||||
|
||||
app_clusters_attr_init();
|
||||
|
||||
/* Register handlers to identify notifications */
|
||||
ZB_AF_SET_IDENTIFY_NOTIFICATION_HANDLER(APP_TEMPLATE_ENDPOINT, identify_cb);
|
||||
ZB_AF_REGISTER_DEVICE_CTX(&app_template_ctx);
|
||||
|
||||
ZB_AF_SET_IDENTIFY_NOTIFICATION_HANDLER(PRST_ZIGBEE_ENDPOINT, identify_cb);
|
||||
|
||||
update_sensors_cb(/*arg=*/0);
|
||||
|
||||
zb_bdb_set_legacy_device_support(1);
|
||||
/* Start Zigbee default thread */
|
||||
zigbee_enable();
|
||||
zb_bdb_set_legacy_device_support(1);
|
||||
|
||||
|
|
|
|||
|
|
@ -0,0 +1,38 @@
|
|||
#ifndef _PRST_ZB_SOIL_MOISTURE_DEFS_
|
||||
#define _PRST_ZB_SOIL_MOISTURE_DEFS_
|
||||
|
||||
#include <zcl/zb_zcl_common.h>
|
||||
|
||||
// Most defines in this file are updated from the ZB_ZCL_DECLARE_TEMP_MEASUREMENT_ATTRIB_LIST,
|
||||
// adapting attributes and IDs to match the mSoilMoisture cluster spec.
|
||||
// Values from https://github.com/Koenkk/zigbee-herdsman/blob/master/src/zcl/definition/cluster.ts#L2570
|
||||
// (msSoilMoisture).
|
||||
|
||||
#define PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID 1032
|
||||
|
||||
// Soil moisture value represented as an uint16.
|
||||
#define PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_VALUE_ID 0x00
|
||||
|
||||
// Required callbacks. ZBOSS will call these.
|
||||
void prst_zcl_soil_moisture_init_server(void);
|
||||
void prst_zcl_soil_moisture_init_client(void);
|
||||
|
||||
#define PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID_SERVER_ROLE_INIT prst_zcl_soil_moisture_init_server
|
||||
#define PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID_CLIENT_ROLE_INIT prst_zcl_soil_moisture_init_client
|
||||
|
||||
#define PRST_ZB_ZCL_SOIL_MOISTURE_CLUSTER_REVISION_DEFAULT ((zb_uint16_t)0x42)
|
||||
|
||||
#define ZB_SET_ATTR_DESCR_WITH_PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_VALUE_ID(data_ptr) \
|
||||
{ \
|
||||
PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_VALUE_ID, \
|
||||
ZB_ZCL_ATTR_TYPE_U16, \
|
||||
ZB_ZCL_ATTR_ACCESS_READ_ONLY | ZB_ZCL_ATTR_ACCESS_REPORTING, \
|
||||
(void*)data_ptr \
|
||||
}
|
||||
|
||||
#define PRST_ZB_ZCL_DECLARE_SOIL_MOISTURE_ATTRIB_LIST(attr_list, value) \
|
||||
ZB_ZCL_START_DECLARE_ATTRIB_LIST_CLUSTER_REVISION(attr_list, PRST_ZB_ZCL_SOIL_MOISTURE) \
|
||||
ZB_ZCL_SET_ATTR_DESC(PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_VALUE_ID, (value)) \
|
||||
ZB_ZCL_FINISH_DECLARE_ATTRIB_LIST
|
||||
|
||||
#endif // _PRST_ZB_SOIL_MOISTURE_DEFS_
|
||||
|
|
@ -1,62 +1,14 @@
|
|||
/*
|
||||
* Copyright (c) 2022 Nordic Semiconductor ASA
|
||||
*
|
||||
* SPDX-License-Identifier: LicenseRef-Nordic-5-Clause
|
||||
*/
|
||||
#ifndef _PRST_ZB_H_
|
||||
#define _PRST_ZB_H_
|
||||
|
||||
#ifndef ZB_RANGE_EXTENDER_H
|
||||
#define ZB_RANGE_EXTENDER_H 1
|
||||
#include "prst_zb_soil_moisture_defs.h"
|
||||
|
||||
/**
|
||||
* @defgroup ZB_DEFINE_DEVICE_RANGE_EXTENDER Range Extender
|
||||
* @{
|
||||
* @details
|
||||
* - @ref ZB_ZCL_IDENTIFY \n
|
||||
* - @ref ZB_ZCL_BASIC
|
||||
*/
|
||||
|
||||
/** Range Extender Device ID*/
|
||||
#define ZB_RANGE_EXTENDER_DEVICE_ID 0x0008
|
||||
|
||||
/** Range extender device version */
|
||||
#define ZB_DEVICE_VER_RANGE_EXTENDER 0
|
||||
|
||||
/** @cond internals_doc */
|
||||
|
||||
/** Range extender IN (server) clusters number */
|
||||
#define ZB_RANGE_EXTENDER_IN_CLUSTER_NUM 5
|
||||
|
||||
/** Range extender OUT (client) clusters number */
|
||||
#define ZB_RANGE_EXTENDER_OUT_CLUSTER_NUM 0
|
||||
|
||||
#define ZB_RANGE_EXTENDER_CLUSTER_NUM \
|
||||
(ZB_RANGE_EXTENDER_IN_CLUSTER_NUM + ZB_RANGE_EXTENDER_OUT_CLUSTER_NUM)
|
||||
|
||||
/** Number of attribute for reporting on Range extender device */
|
||||
#define ZB_RANGE_EXTENDER_REPORT_ATTR_COUNT 3
|
||||
|
||||
typedef struct {
|
||||
zb_uint16_t rel_humidity;
|
||||
zb_uint16_t min_val;
|
||||
zb_uint16_t max_val;
|
||||
} prst_rel_humidity_attrs_t;
|
||||
|
||||
// Power configuration cluster - section 3.3.
|
||||
typedef struct {
|
||||
zb_uint8_t voltage;
|
||||
zb_uint8_t percentage;
|
||||
zb_uint8_t quantity;
|
||||
zb_uint8_t size;
|
||||
zb_uint8_t rated_voltage;
|
||||
zb_uint8_t voltage_min_thres;
|
||||
zb_uint8_t percentage_min_thres;
|
||||
} prst_batt_attrs_t;
|
||||
// ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_VOLTAGE_ID(voltage, ), \
|
||||
// ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_SIZE_ID(size, ), \
|
||||
// ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_QUANTITY_ID(quantity, ), \
|
||||
// ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_RATED_VOLTAGE_ID(rated_voltage, ), \
|
||||
// ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_ALARM_MASK_ID(alarm_mask, ), \
|
||||
// ZB_SET_ATTR_DESCR_WITH_ZB_ZCL_ATTR_POWER_CONFIG_BATTERY_VOLTAGE_MIN_THRESHOLD_ID(voltage_min_threshold, ), \
|
||||
#define PRST_ZB_DEVICE_ID 0x0008
|
||||
#define PRST_ZB_DEVICE_VERSION 0
|
||||
#define PRST_ZB_IN_CLUSTER_NUM 6
|
||||
#define PRST_ZB_OUT_CLUSTER_NUM 0
|
||||
#define PRST_ZB_CLUSTER_NUM (PRST_ZB_IN_CLUSTER_NUM + PRST_ZB_OUT_CLUSTER_NUM)
|
||||
#define PRST_ZB_ATTR_REPORTING_COUNT 4
|
||||
|
||||
#define ZB_DECLARE_RANGE_EXTENDER_CLUSTER_LIST( \
|
||||
cluster_list_name, \
|
||||
|
|
@ -64,7 +16,8 @@ typedef struct {
|
|||
identify_attr_list, \
|
||||
temp_measurement_attr_list, \
|
||||
rel_humidity_attr_list, \
|
||||
batt_att_list) \
|
||||
batt_att_list, \
|
||||
soil_moisture_attr_list) \
|
||||
zb_zcl_cluster_desc_t cluster_list_name[] = \
|
||||
{ \
|
||||
ZB_ZCL_CLUSTER_DESC( \
|
||||
|
|
@ -91,6 +44,12 @@ typedef struct {
|
|||
(rel_humi_attr_list), \
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, \
|
||||
ZB_ZCL_MANUF_CODE_INVALID), \
|
||||
ZB_ZCL_CLUSTER_DESC( \
|
||||
PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID, \
|
||||
ZB_ZCL_ARRAY_SIZE(soil_moisture_attr_list, zb_zcl_attr_t), \
|
||||
(soil_moisture_attr_list), \
|
||||
ZB_ZCL_CLUSTER_SERVER_ROLE, \
|
||||
ZB_ZCL_MANUF_CODE_INVALID), \
|
||||
ZB_ZCL_CLUSTER_DESC( \
|
||||
ZB_ZCL_CLUSTER_ID_POWER_CONFIG, \
|
||||
ZB_ZCL_ARRAY_SIZE(batt_attr_list, zb_zcl_attr_t), \
|
||||
|
|
@ -98,15 +57,6 @@ typedef struct {
|
|||
ZB_ZCL_CLUSTER_SERVER_ROLE, \
|
||||
ZB_ZCL_MANUF_CODE_INVALID)}
|
||||
|
||||
/** @cond internals_doc */
|
||||
|
||||
/**
|
||||
* @brief Declare simple descriptor for Range extender device
|
||||
* @param ep_name - endpoint variable name
|
||||
* @param ep_id - endpoint ID
|
||||
* @param in_clust_num - number of supported input clusters
|
||||
* @param out_clust_num - number of supported output clusters
|
||||
*/
|
||||
#define ZB_ZCL_DECLARE_RANGE_EXTENDER_SIMPLE_DESC(ep_name, ep_id, in_clust_num, out_clust_num) \
|
||||
ZB_DECLARE_SIMPLE_DESC(in_clust_num, out_clust_num); \
|
||||
ZB_AF_SIMPLE_DESC_TYPE(in_clust_num, out_clust_num) \
|
||||
|
|
@ -114,8 +64,8 @@ typedef struct {
|
|||
{ \
|
||||
ep_id, \
|
||||
ZB_AF_HA_PROFILE_ID, \
|
||||
ZB_RANGE_EXTENDER_DEVICE_ID, \
|
||||
ZB_DEVICE_VER_RANGE_EXTENDER, \
|
||||
PRST_ZB_DEVICE_ID, \
|
||||
PRST_ZB_DEVICE_VERSION, \
|
||||
0, \
|
||||
in_clust_num, \
|
||||
out_clust_num, \
|
||||
|
|
@ -124,27 +74,19 @@ typedef struct {
|
|||
ZB_ZCL_CLUSTER_ID_IDENTIFY, \
|
||||
ZB_ZCL_CLUSTER_ID_TEMP_MEASUREMENT, \
|
||||
ZB_ZCL_CLUSTER_ID_REL_HUMIDITY_MEASUREMENT, \
|
||||
PRST_ZB_ZCL_ATTR_SOIL_MOISTURE_CLUSTER_ID, \
|
||||
ZB_ZCL_CLUSTER_ID_POWER_CONFIG, \
|
||||
}}
|
||||
|
||||
/** @endcond */ /* internals_doc */
|
||||
#define ZB_DECLARE_RANGE_EXTENDER_EP(ep_name, ep_id, cluster_list) \
|
||||
ZBOSS_DEVICE_DECLARE_REPORTING_CTX(reporting_ctx_##ep_name, PRST_ZB_ATTR_REPORTING_COUNT); \
|
||||
ZB_ZCL_DECLARE_RANGE_EXTENDER_SIMPLE_DESC(ep_name, ep_id, \
|
||||
PRST_ZB_IN_CLUSTER_NUM, PRST_ZB_OUT_CLUSTER_NUM); \
|
||||
ZB_AF_DECLARE_ENDPOINT_DESC(ep_name, ep_id, ZB_AF_HA_PROFILE_ID, \
|
||||
/*reserved_length=*/0, /*reserved_ptr=*/NULL, \
|
||||
ZB_ZCL_ARRAY_SIZE(cluster_list, zb_zcl_cluster_desc_t), cluster_list, \
|
||||
(zb_af_simple_desc_1_1_t *)&simple_desc_##ep_name, \
|
||||
PRST_ZB_ATTR_REPORTING_COUNT, reporting_ctx_##ep_name, \
|
||||
/*lev_ctrl_count=*/0, /*lev_ctrl_ctx=*/NULL)
|
||||
|
||||
/**
|
||||
* @brief Declare endpoint for Range extender device
|
||||
* @param ep_name - endpoint variable name
|
||||
* @param ep_id - endpoint ID
|
||||
* @param cluster_list - endpoint cluster list
|
||||
*/
|
||||
#define ZB_DECLARE_RANGE_EXTENDER_EP(ep_name, ep_id, cluster_list) \
|
||||
ZBOSS_DEVICE_DECLARE_REPORTING_CTX(reporting_ctx_##ep_name, ZB_RANGE_EXTENDER_REPORT_ATTR_COUNT); \
|
||||
ZB_ZCL_DECLARE_RANGE_EXTENDER_SIMPLE_DESC(ep_name, ep_id, \
|
||||
ZB_RANGE_EXTENDER_IN_CLUSTER_NUM, ZB_RANGE_EXTENDER_OUT_CLUSTER_NUM); \
|
||||
ZB_AF_DECLARE_ENDPOINT_DESC(ep_name, ep_id, ZB_AF_HA_PROFILE_ID, 0, NULL, \
|
||||
ZB_ZCL_ARRAY_SIZE(cluster_list, zb_zcl_cluster_desc_t), cluster_list, \
|
||||
(zb_af_simple_desc_1_1_t *)&simple_desc_##ep_name, \
|
||||
ZB_RANGE_EXTENDER_REPORT_ATTR_COUNT, reporting_ctx_##ep_name, \
|
||||
0, NULL) /* No CVC ctx */
|
||||
|
||||
/*! @} */
|
||||
|
||||
#endif /* ZB_RANGE_EXTENDER_H */
|
||||
#endif // _PRST_ZB_H_
|
||||
|
|
|
|||